Request a quoteRequest a quote

Commissioning reports in French: the terms, the documents and what stays exact on a test sheet.

A commissioning report records that a building's systems were tested and perform as designed. In French it is a rapport de mise en service; start-up is mise en route, a different step with its own records. On a test sheet, values, units and device names must come through exactly, written the French way.

What is a commissioning report?

A commissioning report records that a building’s systems were installed, started, tested and verified to perform as designed, with the test results. On a project specified with the National Master Specification, it closes a set of records. In the version of section 01 91 13, General Commissioning Requirements, issued on a 2012 project we read, these include the start-up documentation, the test and balancing reports and the completed commissioning forms; the commissioning plan has its own section, 01 91 13.13. The Canadian standard for the process, CSA Z320 Building commissioning, is published in English and French.

These are commissioning documents an owner keeps for the life of the building, and on a project delivered in French, the French version is the one the operators read.

Mise en service or mise en route: what is the difference?

Commissioning is mise en service; start-up is mise en route, or mise en marche. The Grand dictionnaire terminologique defines mise en service as the operation that makes a device or machine work for the first time “en effectuant les essais et les réglages nécessaires”, and warns not to confuse it with mise en marche, the act of starting it. Our National Master Specification term base gives the same pair: commissioning = mise en service, start-up = mise en route.

How Canadian sources name commissioning in French (read November 24, 2026)
  • National Master Specification and our NMS term basemise en serviceSection 01 91 13 in French: Mise en service - exigences générales
  • Grand dictionnaire terminologique (OQLF), 2006mise en service; start-up is mise en marche or mise en route"Il ne faut pas confondre la mise en service et la mise en marche" (its English equivalents for mise en service also include starting up)
  • Government of Canada, Guide de commissioning pour les nouveaux bâtimentscommissioning (Cx)The French page keeps the English word

Canadian sources do not all agree. The French version of the NMS uses démarrage in the title of section 25 01 11 (EMCS start-up, verification and commissioning) and mise en route in 23 08 16. A Government of Canada French guide on commissioning new buildings keeps the English word, commissioning (Cx). Use the word the project’s specification uses, and keep it in every record of the set.

Which commissioning documents are there, and what are they called in French?

The NMS commissioning section, as issued on that 2012 project, lists the start-up documentation to submit before commissioning begins: factory and on-site test certificates, pre-start-up inspection reports, signed installation and start-up check lists, start-up reports, and a step-by-step description of the start-up procedures. Then come the test and balancing reports, the performance verification forms and the commissioning report itself.

Commissioning and start-up records in English and French (our NMS term base and the NMS section titles)
  • commissioning planplan de mise en serviceNMS 01 91 13.13
  • commissioning formformulaire de rapport de mise en serviceOur NMS term base; section 01 91 13.16 is Mise en service - formulaires
  • commissioning report (Cx report)rapport de mise en service (rapport MS)Our NMS term base
  • start-up documentationdocuments relatifs à la mise en routeOur NMS term base
  • complete start-up reportrapport complet de mise en routeOur NMS term base
  • installation check listliste de contrôle de l'installationOur NMS term base
  • Performance Verification (PV) report formformulaire de rapport de CP (contrôle de la performance)Our NMS term base
  • Testing, adjusting and balancing (TAB) for HVACessai, réglage et équilibrage de réseaux de CVCANMS 23 05 93
  • balancing reportrapport d'équilibrageOur NMS term base
  • functional testessai fonctionnelOur NMS term base
  • start-up deficiencyanomalie constatée à la mise en routeOur NMS term base
  • Interim Acceptance Certificatecertificat de réception provisoireOur NMS term base
  • Cx agentagent de mise en serviceOur NMS term base
  • demonstration and training for building commissioningdémonstration et formation - mise en service de bâtimentNMS 01 79 00.13

The section titles come from the official NMS; the record names come from our NMS term base, built from the official English and French NMS. The NMS divisions in English and French guide gives every section title in both languages.

What changes when a test sheet is translated?

Values and units stay exactly as measured, and each device name must be the one on the French equipment schedule and label. A test sheet is read across from the schedule and the label on the equipment, so a device named differently in the French is a device the reader cannot find. Units stay as issued; we convert them only when asked.

The way numbers are written does change. In French the decimal sign is “toujours une virgule”, thousands are separated by a non-breaking space, and a non-breaking space separates a value from its unit symbol.

A value on a test sheet, in English and in French (Office québécois de la langue française examples)
  • Decimal35.5 cm35,5 cm
  • Value below one0.6 km0,6 km
  • Thousands21,985 km21 985 km(non-breaking space)
  • Temperature20°C20 °C(non-breaking space)

Exactness here is checked. The section as issued on that 2012 project asks for actual values “within +/- 2 % of recorded values” and for up to 30% of reported results to be verified again. A transposed digit in the French would put a recorded value outside that tolerance on paper. A check sheet repeats across dozens of pieces of equipment, so translate the blank form once, have it approved, then fill it in for every unit.

How are deficiencies handled in the French records?

Our NMS term base gives anomalie constatée à la mise en route for a start-up deficiency, and lacunes ou anomalies for evidence of deficiencies. The section as issued on that 2012 project has deficiencies corrected and approved after each phase, before the next one starts, so each deficiency appears in more than one record: the check sheet that found it, the report that lists it, and the retest that closes it. Give each deficiency the same French wording in all three, so an operator can follow it from the first record to the retest.

How we translate commissioning records

We translate commissioning plans, forms and reports with the specification and the drawings they refer to, against one glossary, so the system and device names in a report are the names in the specification and on the schedules. Our NMS term base holds over 15,000 terms, we have experience across every NMS section, and a second linguist reviews every document. For the platform screen doors of an automated transit line, we translated 32 orders across 14 document types, 308,505 words; 30 of the 32 orders used the client’s own term base. More on the disciplines: mechanical and MEP translation and electrical engineering translation.

Common questions

What is a commissioning report in French?
A rapport de mise en service, or rapport MS in short form, in our NMS term base.
What is the French for start-up report?
Rapport de mise en route; a complete start-up report is a rapport complet de mise en route. Start-up is mise en route, not mise en service.
Is a commissioning checklist the same as a commissioning form?
Both belong to NMS section 01 91 13.16, whose French description covers listes de contrôle et formulaires de rapport. In the 2012 project issue we read, the check lists are filled in during installation and start-up, and the report forms record the tests.
Are test values converted when a report is translated?
No. Values and units stay as issued unless the client asks for a conversion; only the way the numbers are written changes (35.5 becomes 35,5).